clear port protected
SecureStack B3 Configuration Guide 5-49
Example
Thisexampleshowshowtodisplayinformationaboutallprotectedports:
B3(ro)->show port protected
Group id Port
----------------------
1 ge.1.1
1 ge.1.2
1 ge.1.3
clear port protected
Usethiscommandtoremoveaportorgroupfromprotectedmode.
Syntax
clear port protected [port-string] | [group-id]
Parameters
Defaults
Ifnoparametersareentered,allprotectedportsandgroupsarecleared.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoclearprotectedportsge.1.1throughge.1.3:
B3(rw)->clear port protected ge.1.1-3
set port protected name
Usethiscommandtoassignanametoaprotectedportgroupid.
Syntax
set port protected name group-id name
Parameters
Defaults
None.
portstring (Optional)Specifiestheportorportstoremovefromprotectedmode.
groupid (Optional)Specifiestheidofthegrouptoremovefromprotectedmode.
Idcanrangefrom0to2.
groupid Specifiestheidofthisgroup.Idcanrangefrom0to2.
name Specifiesanameforthegroup.Thenamecanbeupto32charactersin
length.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals