show cos settings
10-22 Policy Classification Configuration
Example
ThisexampleshowshowtoclearthepriorityforCoSentry8:
B3(rw)->clear cos settings 8 priority
show cos settings
UsethiscommandtodisplayClassofServiceparameters.
Syntax
show cos settings [cos-list]
Parameters
Defaults
Ifnotspecified,allCoSentrieswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtoshowallCoSsettings:
B3(su)->show cos settings
CoS Index Priority ToS IRL
--------- ---------- ------- -----
0 0 * *
1 1 * *
2 2 * *
3 3 * *
4 4 * *
5 5 * *
6 6 * *
7 7 * *
set cos port-config
Usethiscommandtocreateaportgroupforinboundratelimitingandaddorremoveportsfrom
thegroup.
Syntax
set cos port-config irl group-type-index [name name] [ports port-list] [append] |
[clear]
coslist (Optional)SpecifiesaClassofServiceentrytodisplay.