Page #348 background image
show cos settings
10-22 Policy Classification Configuration
Example
ThisexampleshowshowtoclearthepriorityforCoSentry8:
B3(rw)->clear cos settings 8 priority
show cos settings
UsethiscommandtodisplayClassofServiceparameters.
Syntax
show cos settings [cos-list]
Parameters
Defaults
Ifnotspecified,allCoSentrieswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtoshowallCoSsettings:
B3(su)->show cos settings
CoS Index Priority ToS IRL
--------- ---------- ------- -----
0 0 * *
1 1 * *
2 2 * *
3 3 * *
4 4 * *
5 5 * *
6 6 * *
7 7 * *
set cos port-config
Usethiscommandtocreateaportgroupforinboundratelimitingandaddorremoveportsfrom
thegroup.
Syntax
set cos port-config irl group-type-index [name name] [ports port-list] [append] |
[clear]
coslist (Optional)SpecifiesaClassofServiceentrytodisplay.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
Ports24 or 48 10/100/1000BASE-T ports
Forwarding Rate95.2 Mpps
LayerLayer 2/3
Power SupplyInternal
Redundant Power SupplyOptional
VLANs Supported4094
Uplink Ports4 SFP ports
Dimensions44.0 x 43.7 x 4.4 cm
Weight11.9 lbs (5.4 kg)
MAC Address Table Size16, 000 entries
Jumbo Frame SupportUp to 9, 216 bytes
Power over EthernetPoE+
Operating Temperature0°C to 50°C
Storage Temperature-20 °C to 70 °C
Humidity10% to 95% (non-condensing)