set port broadcast
5-28 Port Configuration
Parameters
Defaults
Ifportstringisnotspecified,broadcaststatusofallportswillbedisplayed.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaythebroadcastsuppressionthresholdsforports1through4:
B3(su)->show port broadcast ge.1.1-4
Port Total BC Threshold
Packets (pkts/s)
----------------------------------------
ge.1.1 0 50
ge.1.2 0 50
ge.1.3 0 40
ge.1.4 0 14881
set port broadcast
Usethiscommandtosetthebroadcastsuppressionthreshold,inpacketspersecond,ononeor
moreports.Thissetsathresholdonthebroadcasttrafficthatisreceivedandswitchedouttoother
ports.
Syntax
set port broadcast port-string threshold-val
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleconfiguresports1through5withabroadcastlimitof50pps:
B3(su)->set port broadcast ge.1.1-5 50
portstring (Optional)Selecttheportsforwhichtoshowbroadcastsuppression
thresholds.Foradetaileddescriptionofpossibleportstringvalues,refer
toPortSt ringSyntaxUsedintheCLIonpage51.
portstring Selecttheportsforwhichtoconfigurebroadcastsuppressionthresholds.
Foradetaileddescriptionofpossibleportstringvalues,refertoPort
StringSyntaxUsedintheCLIonpage51.
thresholdval Setsthepacketspersecondthresholdonbroadcasttraffic.Maximum
valueis1488 10forFast
Ethernetportsand1488100forGigabitports.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals