set system enhancedbuffermode
3-14 Basic Configuration
Examples
Thisexampleshowshowtodisplaythesystem’sCPUutilization:
B3(ro)->show system utilization cpu
Total CPU Utilization:
Switch CPU 5 sec 1 min 5 min
-----------------------------------------------
1 1 3% 1% 1%
Thisexampleshowshowtodisplaythesystem’soverallmemoryusage:
B3(ro)->show system utilization storage
Storage Utilization:
Type Description Size(Kb) Available (Kb)
---------------------------------------------------------------
RAM RAM device 262144 97173
Flash Images, Config, Other 31095 8094
Thisexampleshowshowtodisplayinformationabouttheprocessesrunningonthesystem.Only
partialoutputisshown.
B3(ro)->show system utilization process
TID Name 5Sec 1Min 5Min
8d45148 captureTask 0.00% 0.00% 0.00%
8e264f8 poe_monitor 0.00% 0.01% 0.05%
8ea6d38 poe_read 0.80% 0.22% 0.20%
8eb7140 vlanDynEg 0.00% 0.00% 0.00%
8f0be10 tcdpSendTask 0.00% 0.00% 0.00%
8f1c0e8 tcdpTask 0.00% 0.00% 0.00%
set system enhancedbuffermode
Usethiscommandtoenableordisableenhancedbuffermode,whichoptimizesbuffer
distributionfornonstackingsingleCoSqueueoperation.Executingthiscommandwillresetthe
switch,sothesystempromptsyoutoconfirmwhetheryouwanttoproceed.
Syntax
set system enhancedbuffermode {enable | disable}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
enable|disable Enablesordisablesenhancedbuffermode.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals