show port vlan
SecureStack B3 Configuration Guide 8-7
Commands
show port vlan
UsethiscommandtodisplayportVLANidentifier(PVID)information.PVIDdeterminesthe
VLANtowhichalluntaggedframesreceivedononeormoreportswillbeclassified.
Syntax
show port vlan [port-string]
Parameters
Defaults
Ifport‐stringisnotspecified,portVLANinformationforallportswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplayPVIDsassignedtoge.2.1through6.Inthiscase,untagged
framesreceivedontheseportswillbeclassifiedtoVLAN1:
B3(su)->show port vlan ge.2.1-6
ge.2.1 is set to 1
ge.2.2 is set to 1
ge.2.3 is set to 1
ge.2.4 is set to 1
ge.2.5 is set to 1
ge.2.6 is set to 1
set port vlan
UsethiscommandtoconfigurethePVID(portVLANidentifier)foroneormoreports.
For information about... Refer to page...
show port vlan 8-7
set port vlan 8-7
clear port vlan 8-8
show port ingress filter 8-9
set port ingress filter 8-9
show port discard 8-10
set port discard 8-11
portstring (Optional)DisplaysPVIDinformationforspecificport(s).Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLIonpage 5 1.