set rmon alarm status
14-10 RMON Configuration
fthresh‐0
revent‐0
fevent‐0
owner‐monitor
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoconfigurearisingRMONalarm.Thisentrywillconductmonitoring
ofthedeltabetweensamplesevery30seconds:
B3(rw)->set rmon alarm properties 3 interval 30 object
1.3.6.1.4.1.5624.1.2.29.1.2.1.0 type delta rthresh 1 revent 2 owner Manager
set rmon alarm status
UsethiscommandtoenableanRMONalarmentry.Analarmisanotificationthatastatistical
sampleofamonitoredvariablehascrossedaconfiguredthreshold.
Syntax
set rmon alarm status index enable
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
AnRMONalarmentrycanbecreatedusingthiscommand,configuredusingthesetrmonalarm
propertiescommand(“setrmonalarmpropertiesonpage 149),thenenabledusingthis
command.AnRMONalarmentrycanbecreatedandconfiguredatthesametimebyspecifying
anunusedindexwiththe
setrmonalarmpropertiescommand.
Example
ThisexampleshowshowtoenableRMONalarmentry3:
B3(rw)->set rmon alarm status 3 enable
clear rmon alarm
UsethiscommandtodeleteanRMONalarmentry.
index Specifiesanindexnumberforthisentry.Maximumnumberorentriesis
50.Maximumvalueis65535.
enable Enablesthisalarmentry.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals