clear spantree adminedge
7-38 Spanning Tree Configuration
Syntax
set spantree adminedge port-string {true | false}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
Thedefaultbehavioroftheedgeportadministrativestatusbeginswiththevaluesettofalse
initiallyafterthedeviceispoweredup.IfaSpanningTreeBDPUisnotreceivedontheportwithin
afewseconds,thestatussettingchangestotrue.
Example
Thisexampleshowshowtosetge.1.11asanedgeport:
B3(su)->set spantree adminedge ge.1.11 true
clear spantree adminedge
UsethiscommandtoresetaSpanningTreeporttononedgestatus.
Syntax
clear spantree adminedge port-string
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoresetge.1.11asanonedgeport:
B3(su)->clear spantree adminedge ge.1.11
portstring Specifiestheedgeport.Foradetaileddescriptionofpossibleportstring
values,refertoPortStringSyntax UsedintheCLIonpage 51.
true|false Enables(true)ordisables(false)thespecifiedportasaSpanningTreeedge
port.
portstring Specifiesport(s)onwhichtoresetedgeportstatus.Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLIonpage 5 1.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals