EasyManua.ls Logo

Enterasys SecureStack B3

Enterasys SecureStack B3
582 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
clear summertime
3-18 Basic Configuration
Syntax
set summertime recurring start_week start_day start_month start_hr_min end_week
end_day end_month end_hr_min [offset_minutes]
Parameters
Defaults
Ifanoffsetisnotspecified,nonewillbeapplied.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowsetdaylightsavingstimetorecurstartingonthefirstSundayofAprilat
2a.m.andendingthelastSundayofOctoberat2a.m.withanoffsettimeofonehour:
B3(su)->set summertime recurring first Sunday April 02:00 last Sunday October
02:00 60
clear summertime
Usethiscommandtoclearthedaylightsavingstimeconfiguration.
Syntax
clear summertime
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
start_week Specifiestheweekofthemonthtorestartdaylightsavingstime.Valid
valuesare:first,second,third,fourth,andlast.
start_day Specifiesthedayoftheweektorestartdaylightsavingstime.
start_hr_min Specifiesthetimeofdaytorestartdaylightsavingstime.Forma tis
hh:mm.
end_week Specifies
theweekofthemonthtoenddaylightsavingstime.
end_day Specifiesthedayoftheweektoenddaylightsavingstime.
end_hr_min Specifiesthetimeofdaytoenddaylightsavingstime.Formatishh:mm.
offset_minutes (Optional)Specifiestheamountoftimeinminutestooffsetdaylight
savingstimefromthenon
daylightsavingstimesystemsetting.Valid
valuesare1‐1440.

Table of Contents

Related product manuals