Loading...
ip irdp minadvertinterval
SecureStack B3 Configuration Guide 18-11
Mode
Interfaceconfiguration:B3(su)>router(Configif(Vlan1))#
Example
ThisexampleshowshowtosetthemaximumIRDPadvertisementintervalto1000secondsonthe
VLAN1interface:
B3(su)->router(Config)#interface vlan 1
B3(su)->router(Config-if(Vlan 1))#ip irdp maxadvertinterval 1000
ip irdp minadvertinterval
UsethiscommandtosettheminimumintervalinsecondsbetweenIRDPadvertisements.Theno
formofthiscommanddeletesthecustomholdtimesetting,andresetstheminimum
advertisementintervaltothedefaultvalueofthreefourthsofthemaxadvertintervalvalue,which
isequalto450seconds.
Syntax
ip irdp minadvertinterval interval
no irdp minadvertinterval
Parameters
Defaults
None.
Mode
Interfaceconfiguration:B3(su)>router(Configif(Vlan1))#
Example
ThisexampleshowshowtosettheminimumIRDPadvertisementintervalto500secondsonthe
VLAN1interface:
B3(su)->router(Config)#interface vlan 1
B3(su)->router(Config-if(Vlan 1))#ip irdp minadvertinterval 500
ip irdp holdtime
UsethiscommandtosetthelengthoftimeinsecondsIRDPadvertisementsareheldvalid.Theno
formofthiscommandresetstheholdtimetothedefaultvalueofthreetimesthe
maxadvertintervalvalue,whichisequalto1800seconds.
Syntax
ip irdp holdtime holdtime
no irdp holdtime
interval Specifiesaminimumadvertisementintervalinseconds.Validvaluesare
3to1800.

Table of Contents