EasyManua.ls Logo

Enterasys SecureStack B3 User Manual

Enterasys SecureStack B3
582 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #120 background imageLoading...
Page #120 background image
clear ciscodp
4-12 Discovery Protocol Configuration
•IftheswitchportisconfiguredtoaCiscoDPtruststateofuntrusted(trustedno),thissetting
iscommunicatedtotheCiscoIPphoneinstructingittooverwritethe802.1ptagoftraffic
transmittedbythedeviceconnectedtoitto0,bydefault,ortothevaluespecified
bythecos
parameterofthiscommand.
•Thereisaonetoonecorrelationbetweenthevaluesetwiththecosparameterandthe802.1p
valueassignedtoingressedtrafficbytheCiscoIPphone.Avalueof0 equatestoan802.1p
priorityof0.Therefore,avalueof7
isgiventhehighestpriority.
Examples
ThisexampleshowshowtosettheCiscoDPportvoiceVLANIDto3onportge.1.6and enable
theportoperationalstate.
B3(rw)->set ciscodp port status enable vvid 3 ge.1.6
ThisexampleshowshowtosettheCiscoDPextendedtrustmodetountrustedonportge.1.5and
settheCoSpriorityto1.
B3(rw)->set ciscodp port trusted no cos 1 ge.1.5
clear ciscodp
UsethiscommandtocleartheCiscodiscoveryprotocolbacktothedefaultvalues.
Syntax
clear ciscodp [status | timer | holdtime | {port {status | vvid | trust | cos}
[port-string]}]
Parameters
Defaults
Ifnoparametersareentered,allCiscoDPparametersareresettothedefaultsgloballyandforall
ports.
Mode
Switchmode,readwrite.
Note: The Cisco Discovery Protocol must be globally enabled using the set ciscodp status
command before operational status can be set on individual ports.
status ClearsglobalCiscoDPenablestatustodefaultofauto.
timer ClearsthetimebetweenCiscoDPPDUtransmissionstodefaultof60
seconds.
holdtime ClearsthetimetoliveforCiscoDPPDUdatatodefaultof180seconds.
port ClearstheCiscoDPportconfiguration.
status Clearstheindividualportoperationalstatustothedefaultof
enabled.
vvid ClearstheindividualportvoiceVLANforCiscoDPPDUtransmission
to0.
trust Clearsthetrustmodeconfigurationoftheporttotrusted.
cos ClearstheCoSpriorityforuntrustedtrafficoftheportto0.
portstring (Optional)Specifiestheport(s)onwhichstatuswillbeset.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
Ports24 or 48 10/100/1000BASE-T ports
Forwarding Rate95.2 Mpps
LayerLayer 2/3
Power SupplyInternal
Redundant Power SupplyOptional
VLANs Supported4094
Uplink Ports4 SFP ports
Dimensions44.0 x 43.7 x 4.4 cm
Weight11.9 lbs (5.4 kg)
MAC Address Table Size16, 000 entries
Jumbo Frame SupportUp to 9, 216 bytes
Power over EthernetPoE+
Operating Temperature0°C to 50°C
Storage Temperature-20 °C to 70 °C
Humidity10% to 95% (non-condensing)