show rmon alarm
14-8 RMON Configuration
Syntax
show rmon alarm [index]
Parameters
Defaults
Ifindexisnotspecified,informationabou tallRMONalarmentrieswillbedisplayed.
Mode
Switchcommand,read‐only.
Example
ThisexampleshowshowtodisplayRMONalarmentry3:
B3(rw)->show rmon alarm 3
Index 3
---------------------
Owner = Manager
Status = valid
Variable = 1.3.6.1.4.1.5624.1.2.29.1.2.1.0
Sample Type = delta Startup Alarm = rising
Interval = 30 Value = 0
Rising Threshold = 1 Falling Threshold = 0
Rising Event Index = 2 Falling Event Index = 0
Table 14‐2providesanexplanationofthecommandoutput.
index (Optional)DisplaysRMONalarmentriesforaspecificentryindexID.
Table 14-2 show rmon alarm Output Details
Output What It Displays...
Index Index number for this alarm entry.
Owner Text string identifying who configured this entry.
Status Whether this event entry is enabled (valid) or disabled.
Variable MIB object to be monitored.
Sample Type Whether the monitoring method is an absolute or a delta sampling.
Startup Alarm Whether alarm generated when this entry is first enabled is rising, falling, or either.
Interval Interval in seconds at which RMON will conduct sample monitoring.
Rising Threshold Minimum threshold for causing a rising alarm.
Falling Threshold Maximum threshold for causing a falling alarm.
Rising Event Index Index number of the RMON event to be triggered when the rising threshold is
crossed.
Falling Event Index Index number of the RMON event to be triggered when the falling threshold is
crossed.