set port advertise
SecureStack B3 Configuration Guide 5-15
Example
ThisexampleshowshowtodisplayadvertisementstatusforGigabitports13and14:
B3(su)->show port advertise ge.1.13-14
ge.1.13 capability advertised remote
-------------------------------------------------
10BASE-T yes yes yes
10BASE-TFD yes yes yes
100BASE-TX yes yes yes
100BASE-TXFD yes yes yes
1000BASE-T no no no
1000BASE-TFD yes yes yes
pause yes yes no
ge.1.14 capability advertised remote
-------------------------------------------------
10BASE-T yes yes yes
10BASE-TFD yes yes yes
100BASE-TX yes yes yes
100BASE-TXFD yes yes yes
1000BASE-T no no no
1000BASE-TFD yes yes yes
pause yes yes no
set port advertise
Usethiscommandtoconfigurewhataportwilladvertiseforspeed/duplexcapabilitiesinauto
negotiation.
Syntax
set port advertise {port-string}{10t | 10tfd | 100tx | 100txfd | 1000t | 1000tfd
| pause}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
portstring Selecttheportsforwhichtoconfigureadvertisements.Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLIonpage51.
10t Advertise10BASEThalfduplexmode.
10tfd Advertise10BASETfullduplexmode.
100tx Advertise100BASETX
halfduplexmode.
100txfd Advertise100BASETXfullduplexmode.
1000t Advertise1000BASEThalfduplexmode.
1000tfd Advertise1000BASETfullduplexmode.
pause AdvertisePAUSEforfullduplexlinks.

Table of Contents