set lldp tx-interval
SecureStack B3 Configuration Guide 4-23
set lldp tx-interval
Usethiscommandtosetthetime,inseconds,betweensuccessiveLLDPframetransmissions
initiatedbychangesintheLLDPlocalsysteminformation.
Syntax
set lldp tx-interval frequency
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexamplesetsthetransm itintervalto20seconds.
B3(rw)->set lldp tx-interval 20
set lldp hold-multiplier
UsethiscommandtosetthetimetolivevalueusedinLLDPframessentbythisdevice.Thetime
toliveforLLDPDUdataiscalculatedbymultiplyingthetransmitintervalbytheholdmultiplier
value.
Syntax
set lldp hold-multiplier multiplier-val
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexamplesetsthetransm itintervalto20secondsandtheholdmultiplierto5,whichwill
configureatimetoliveof100tobeusedintheTTL fieldintheLLDPDUheader.
B3(rw)->set lldp tx-interval 20
frequency SpecifiesthenumberofsecondsbetweentransmissionsofLLDP
frames.Valuecanrangefrom5to32,768seconds.Thedefaultis30
seconds.
multiplierval Specifiesthemultipliertoapplytothetransmitintervaltodetermine
thetimetolivevalue.Valuecanrangefrom2to10.Defaultvalueis
4.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals