set ipv6
19-2 IPv6 Management
Defaults
None.
Mode
Switchmode,readonly.
Example
ThisexampleshowshowtodisplayIPv6managementfunctionstatus.
B3(ro)->show ipv6 status
IPv6 Administrative Mode: Disabled
set ipv6
UsethiscommandtogloballyenableordisabletheIPv6managementfunction.
Syntax
set ipv6 {enable | disable}
Parameters
Defaults
Bydefault,IPv6managementisdisabled.
Mode
Switchmode,readwrite.
Usage
WhenyouenableIPv6managementontheswitch,thesystemautomaticallygeneratesalinklocal
hostaddressfortheswitchfromthehostMACaddress.YoucansetadifferenthostIPv6address
withthesetipv6addresscommand.
Example
ThisexampleshowshowtoenableIPv6management.
B3(su)-> set ipv6 enable
B3(su)->show ipv6 status
IPv6 Administrative Mode: Enabled
B3(su)->show ipv6 address
Name IPv6 Address
------------ ----------------------------------------
host FE80::201:F4FF:FE5C:2880/64
set ipv6 address
UsethiscommandtoconfigureIPv6globaladdressinginformation.
enable|disable EnableordisabletheIPv6managementfunction.