set macauthentication portquietperiod
SecureStack B3 Configuration Guide 20-25
set macauthentication portquietperiod
Thissetsthenumberofsecondsfollowingafailedauthenticationbeforeanotherattemptmaybe
madeontheport.
Syntax
set macauthentication portquietperiod time port-string
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexamplesetsport1towait5secondsafterafailedauthenticationattemptbeforeanew
attemptcanbemade:
B3(su)->set macauthentication portquietperiod 5 ge.1.1
clear macauthentication portquietperiod
Thissetsthequietperiodbacktothedefaultvalue.
Syntax
clear macauthentication portquietperiod [port-string]
Parameters
Defaults
Ifaportstringisnotspecifiedthenallportswillbesettothedefaultportquietperiod.
Mode
Switchcommand,readwrite.
Example
Thisexampleresetsthedefaultquitperiodonport1:
B3(su)->clear macauthentication portquietperiod ge.1.1
time Periodinsecondstowaitafterafailedauthentication
portstring Specifiestheportsforwhichthequitperiodistobeapplied.Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLIonpage 5 1.
portstring (Optional)Specifiestheportsforwhichthequietperiodistobereset.Fora
detaileddescriptionofpossibleportstringvalues,refertoPortString
SyntaxUsedintheCLIonpage 51.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals