clear policy port
SecureStack B3 Configuration Guide 10-15
Parameters
Defaults
None.
Mode
Switchcommand,read‐write.
Example
ThisexampleshowshowtoallowGigabitEthernetports5through15inslot1totransmitframes
accordingtopolicyprofile1:
B3(su)->set policy port ge.1.5-15 1
clear policy port
Usethiscommandtoremoveapolicyprofilefromoneormoreports.
Syntax
clear policy port port-string profile-index
Parameters
Defaults
None.
Mode
Switchcommand,read‐write.
Example
Thisexampleshowshowtoremovepolicyprofile10fromport21inslot1:
B3(rw)->clear policy port ge.1.21 10
port‐string Specifiestheport(s)toaddtothepolicyprofile.Foradetaileddescription
ofpossibleport‐stringvalues,referto“PortStringSyntaxUsedintheCLI”
onpage 5‐1.
profile‐index SpecifiestheIDofthepolicyprofile(role)towhichtheport(s)willbe
added.Thisvalue
mustmatchtheprofile‐indexvalueassignedusingthe
setpolicyprofilecommand(“setpolicyprofile”onpage 10 ‐3)inorder
forapolicyprofiletobeactiveonthespecifiedport.
port‐string Specifiestheport(s)fromwhichtoremovethepolicyprofile.Fora
detaileddescriptionofpossibleport‐stringvalues,referto“PortString
SyntaxUsedintheCLI”onpage 5‐1.
profile‐index SpecifiestheIDofthepolicyprofile(role) towhichtheport(s)willbe
added.This
valuemustmatchtheprofile‐indexvalueassignedusingthe
setpolicyprofilecommand(“setpolicyprofile”onpage 10 ‐3)inorder
forapolicyprofiletobeactiveonthespecifiedport.