Configuring SNMP Target Addresses
SecureStack B3 Configuration Guide 6-25
Configuring SNMP Target Addresses
Purpose
ToreviewandconfigureSNMPtargetaddresseswhichwillreceiveSNMPnotificationmessages.
AnaddressconfigurationcanbelinkedtooptionalSNMPtransmit,ortarget,parameters(suchas
timeout,retrycount,andUDPport)setwiththesetsnmptargetparamscommand((page623)).
Commands
show snmp targetaddr
UsethiscommandtodisplaySNMPtargetaddressinformation.
Syntax
show snmp targetaddr [targetAddr] [volatile | nonvolatile | read-only]
Parameters
Defaults
IftargetAddrisnotspecified,entriesforalltargetaddressnameswillbedisplayed.
Ifnotspecified,entriesofallstoragetypeswillbedisplayedforatargetaddress.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaySNMPtargetaddressinformation:
B3(su)->show snmp targetaddr
Target Address Name = labmachine
Tag List = v2cTrap
IP Address = 10.2.3.116
UDP Port# = 162
Target Mask = 255.255.255.255
Timeout = 1500
Retry count = 4
Parameters = v2cParams
Storage type = nonVolatile
Row status = active
For information about... Refer to page...
show snmp targetaddr 6-25
set snmp targetaddr 6-26
clear snmp targetaddr 6-27
targetAddr (Optional)Displaysinformationforaspecifictargetaddressname.
volatile|nonvolatile
|readonly
(Optional)Whentargetaddressisspecified,displaystargetaddress
informationforaspecificstoragetype.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals