RM0453 Rev 1 825/1461
RM0453 Advanced-control timer (TIM1)
829
Note: Refer to Figure 171: Break and Break2 circuitry overview.
Bit 10 BK2CMP1P: BRK2 COMP1 input polarity
This bit selects the COMP1 input sensitivity. It must be programmed together with the BK2P
polarity bit.
0: COMP1 input polarity is not inverted (active low if BK2P=0, active high if BK2P=1)
1: COMP1 input polarity is inverted (active high if BK2P=0, active low if BK2P=1)
Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits
in TIMx_BDTR register).
Bit 9 BK2INP: BRK2 BKIN2 input polarity
This bit selects the BKIN2 alternate function input sensitivity. It must be programmed
together with the BK2P polarity bit.
0: BKIN2 input polarity is not inverted (active low if BK2P=0, active high if BK2P=1)
1: BKIN2 input polarity is inverted (active high if BK2P=0, active low if BK2P=1)
Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits
in TIMx_BDTR register).
Bits 8:3 Reserved, must be kept at reset value.
Bit 2 BK2CMP2E: BRK2 COMP2 enable
This bit enables the COMP2 for the timer’s BRK2 input. COMP2 output is ‘ORed’ with the
other BRK2 sources.
0: COMP2 input disabled
1: COMP2 input enabled
Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits
in TIMx_BDTR register).
Bit 1 BK2CMP1E: BRK2 COMP1 enable
This bit enables the COMP1 for the timer’s BRK2 input. COMP1 output is ‘ORed’ with the
other BRK2 sources.
0: COMP1 input disabled
1: COMP1 input enabled
Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits
in TIMx_BDTR register).
Bit 0 BK2INE: BRK2 BKIN input enable
This bit enables the BKIN2 alternate function input for the timer’s BRK2 input. BKIN2 input is
‘ORed’ with the other BRK2 sources.
0: BKIN2 input disabled
1: BKIN2 input enabled
Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits
in TIMx_BDTR register).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ST STM32WL5 Series and is the answer not in the manual?

ST STM32WL5 Series Specifications

General IconGeneral
BrandST
ModelSTM32WL5 Series
CategoryMicrocontrollers
LanguageEnglish

Related product manuals