3-18 Sun Blade 1500 Service, Diagnostics, and Troubleshooting Manual December 2004
3.3.2 prtdiag Command
The prtdiag command displays configuration and diagnostic information for a
system. The diagnostic information identifies any failed component in the system.
The prtdiag command is located in the /usr/platform/platform-name/sbin/
directory.
Note – The prtdiag command might indicate a slot number different than that
identified elsewhere in this manual. This is normal.
3.3.2.1 Options
TABLE 3-7 describes options for the prtdiag command and how those options can
help troubleshoot the Sun Blade 1500 workstation.
3.3.2.2 Examples
The following examples show output for the prtdiag command and its options.
TABLE 3-7 Options for prtdiag
Option Description How It Can Help
No option Lists system components. Identifies CPU timing and PCI cards installed.
-v
Verbose mode. Displays the
time of the most recent AC
power failure, the most recent
hardware fatal error
information, and (if applicable)
environmental status.
Provides the same information as no option. Additionally
lists fan status, temperatures, ASIC, and PROM revisions.