6-4 Sun Blade 1500 Service, Diagnostics, and Troubleshooting Manual December 2004
To change a parameter value, use the setenv command. For example:
This example enables diagnostics.
Note – Parameters that end with a question mark (?) can only be set true or
false.
6.1.2 Configuration Parameter Default Values
Typing set-defaults resets all parameters to their default values. TABLE 6-2 lists
the NVRAM configuration parameters, the default values, and a description.
ok setenv diag-switch? true
TABLE 6-2 NVRAM Configuration Parameter Default Values
Parameter Default Value Description
asr-policy normal Reserved.
test-args The arguments which configure OpenBoot
Diagnostics.
diag-passes 1 The number of passes that diagnostics are
to make before continuing to boot.
local-mac-address? true A value of true means to use the MAC
address within the motherboard.
fcode-debug? false A value of false disables debugging of
Fcode.
scsi-initiator-id 7 The identifying number of any SCSI host
bus adapter.
oem-logo no default The bitmap of a custom OEM logo.
oem-logo? false A value of false disables use of a custom
logo.
oem-banner no default The text of a custom OEM banner.
oem-banner? false A value of false disables use of a custom
banner.
ansi-terminal? true A value of true enables the terminal
emulator to interpret ANSI escape
sequences.