Figure 4-7 Format of peripheral enable register 0 (PER0) (3/3)
Address: 40020 420H After reset: 00H R/W
symbol
PER0
TM41EN
Provides control of the input clock of the general-purpose timer unit 1
0
Stop supplying the input clock.
 used by universal timer unit 1.
 1 is in a reset state.
1
An input clock is provided.
 1.
TM40EN
Provides control of the input clock of the general-purpose timer unit 0
0
Stop supplying the input clock.
 0.
 0 is in the reset state.
1
An input clock is provided.

7
6
5
4
3
2
2
1
0
RTCEN
IRDAEN
ADCEN
IICAEN
SCI1EN
SCI0EN
TM41EN
TM40EN