Page #1052 background imageLoading...
Page #1052 background image
Controller area network (bxCAN) RM0390
1052/1328 RM0390 Rev 4
The transmit interrupt can be generated by the following events:
Transmit mailbox 0 becomes empty, RQCP0 bit in the CAN_TSR register set.
Transmit mailbox 1 becomes empty, RQCP1 bit in the CAN_TSR register set.
Transmit mailbox 2 becomes empty, RQCP2 bit in the CAN_TSR register set.
The FIFO 0 interrupt can be generated by the following events:
Reception of a new message, FMP0 bits in the CAN_RF0R register are not ‘00’.
FIFO0 full condition, FULL0 bit in the CAN_RF0R register set.
FIFO0 overrun condition, FOVR0 bit in the CAN_RF0R register set.
The FIFO 1 interrupt can be generated by the following events:
Reception of a new message, FMP1 bits in the CAN_RF1R register are not ‘00’.
FIFO1 full condition, FULL1 bit in the CAN_RF1R register set.
FIFO1 overrun condition, FOVR1 bit in the CAN_RF1R register set.
The error and status change interrupt can be generated by the following events:
Error condition, for more details on error conditions refer to the CAN Error Status
register (CAN_ESR).
Wakeup condition, SOF monitored on the CAN Rx signal.
Entry into Sleep mode.
30.9 CAN registers
The peripheral registers have to be accessed by words (32 bits).
30.9.1 Register access protection
Erroneous access to certain configuration registers can cause the hardware to temporarily
disturb the whole CAN network. Therefore the CAN_BTR register can be modified by
software only while the CAN hardware is in initialization mode.
Although the transmission of incorrect data will not cause problems at the CAN network
level, it can severely disturb the application. A transmit mailbox can be only modified by
software while it is in empty state, refer to Figure 390: Transmit mailbox states.
The filter values can be modified either deactivating the associated filter banks or by setting
the FINIT bit. Moreover, the modification of the filter configuration (scale, mode and FIFO
assignment) in CAN_FMxR, CAN_FSxR and CAN_FFAR registers can only be done when
the filter initialization mode is set (FINIT=1) in the CAN_FMR register.
30.9.2 CAN control and status registers
Refer to Section 1.1 for a list of abbreviations used in register descriptions.
CAN master control register (CAN_MCR)
Address offset: 0x00
Reset value: 0x0001 0002

Table of Contents

Other manuals for ST STM32F446 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ST STM32F446 Series and is the answer not in the manual?

ST STM32F446 Series Specifications

General IconGeneral
BrandST
ModelSTM32F446 Series
CategoryMicrocontrollers
LanguageEnglish

Related product manuals