SUBTASK 47-11-01-420-009
(4) Do these steps to connect the clamp [11] (Figure 402, View F):
(a) Apply epoxy primer, C50285, to the contact surfaces on the clamp [11].
WARNING
KRYTOX 240AC IS AN AGENT THAT IS POISONOUS AND AN IRRITANT.
MAKE SURE ALL PERSONS OBEY THE PRECAUTIONS WHEN KRYTOX
240AC IS USED.
DO NOT USE IN AREAS WHERE THERE IS HIGH HEAT, SPARKS, OR
FLAMES.
CLOSE THE CONTAINER WHEN NOT USED.
DO NOT GET KRYTOX 240AC IN THE EYES, ON THE SKIN, OR ON
YOUR CLOTHES.
DO NOT BREATHE THE GAS.
DO NOT EAT KRYTOX 240AC.
(b) Apply a thin layer of Krytox 240AC perfluoropolyether grease, D50063, to the new
O-ring [12].
(c) Install the new O-ring [12] and clamp [11] between the inlet port, on the air separation
module [1], and the overtemperature shutoff valve [10].
(d) Tighten the clamp [11] to 47 ±3 in-lb (5.3 ±0.3 N·m)
SUBTASK 47-11-01-420-010
(5) Connect the aft part of the NEADS duct [27] to the rear spar (Figure 402, View B).
SUBTASK 47-11-01-420-011
(6) Connect the aft part of the muscle air duct [9] to the air supply duct (Figure 402, View B).
SUBTASK 47-11-01-420-012
(7) Connect the oxygen sensor tube [47] to the high flow valve [14] (Figure 402, View D).
SUBTASK 47-11-01-420-013
(8) Do these steps to connect the tube [46] and bonding jumpers (Figure 402, View C):
(a) Connect the tube [46] to the reducer tee on the NEADS duct [27].
(b) Prepare these components for an electrical mating surface bond (SWPM 20-20-00):
1) Clean the contact surfaces on the NEADS duct [27].
NOTE: Where the two clamps [42] are installed.
2) Contact surfaces on both clamps [42].
3) bonding jumper [41]
4) bonding jumper [45]
(c) Install the bolt [40], washers [44], and bonding jumper [41] to the clamp [42].
NOTE: Located aft of the reducer tee.
(d) Install the bolt [40], washers [44], and bonding jumper [45] to the clamp [42].
NOTE: Located forward of the swivel tee.
SUBTASK 47-11-01-420-014
(9) Do these steps to install the bonding jumper [56]:
(a) Prepare the bonding jumper [56] and jumper tab [61] for an electrical mating surface
bond (SWPM 20-20-00):
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
47-11-01
Page 443
D633A101-ILF Oct 15/2019
ECCN 9E991 BOEING PROPRIETARY - Copyright © Unpublished Work - See title page for details
EFFECTIVITY
ILF 402, 452, 509, 510, 523, 525-528, 568, 569, 576, 577, 581, 583, 585, 588-590,
592-599, 601-603, 606, 607, 610-615, 620, 625-627, 691-699, 833-835, 838, 971, 980-999;
ILF 101, 151, 156-199, 301, 304, 308, 310, 314, 315, 317-319, 323, 331-399, 401, 405,
406, 409, 410, 412, 416, 424, 425, 427-429, 451, 501-504, 507, 508, 512-514, 516, 518,
524, 531-533, 535-537, 541, 542, 552-556, 560-562, 567, 571-575, 671, 672, 686, 703,
707-710, 803-813, 821, 822, 831, 832, 836, 837, 841, 842, 851, 852, 854-858, 861-863,
871-874, 947, 948, 968-970, 972, 973 POST SB 737-47-1003

Table of Contents

Related product manuals