(q) Make sure these lights come on:
1) 2 GEN OFF BUS
2) 2 SOURCE OFF
(r) Make sure these lights on the P5-4 panel stay off:
1) 2 TRANSFER BUS OFF
2) 1 TRANSFER BUS OFF
3) 1 SOURCE OFF
4) 1 GEN OFF BUS
(s) Set the GEN 2 switch to the ON position.
(t) Make sure these lights go off:
1) 2 GEN OFF BUS
2) 2 SOURCE OFF
(u) Shut down both engines. To shut down the engines, do this task: Stop the Engine
Procedure (Usual Engine Stop), TASK 71-00-00-700-819-F00.
F. Put the airplane in its usual condition.
SUBTASK 24-21-00-860-009
(1) Do this task: Return the Airplane to the Ground Mode, TASK 32-09-00-860-802.
SUBTASK 24-21-00-860-010
(2) Do this task: Remove Electrical Power, TASK 24-22-00-860-812.
END OF TASK