B. References
Reference Title
24-22-00-860-812 Remove Electrical Power (P/B 201)
C. Tools/Equipment
NOTE: When more than one tool part number is listed under the same "Reference" number, the
tools shown are alternates to each other within the same airplane series. Tool part numbers
that are replaced or non-procurable are preceded by "Opt:", which stands for Optional.
Reference Description
COM-1550 Bonding Meters - Approved, Intrinsically Safe (Approved for use in
Class I, Divisions I & II hazardous (classified) locations. Outside
these hazardous locations, COM-614 can be used in lieu of
COM-1550).
737-600, -700, -800
Part #: 620LK Supplier: 1CRL2
Part #: M1 Supplier: 3AD17
Part #: T477W (C15292) Supplier: 01014
Opt Part #: M1B Supplier: 3AD17
COM-1793 Multimeter - Digital/Analog (or equivalent meter meets task
requirements)
737-600, -700, -800
Part #: 117 Supplier: 89536
Part #: 260-8XPI Supplier: 55026
Part #: 287 Supplier: 89536
Part #: 289 Supplier: 89536
Part #: 87V Supplier: 89536
Part #: FLUKE 27 II Supplier: 89536
Part #: FLUKE-77-4 Supplier: 89536
Opt Part #: 187 Supplier: 89536
Opt Part #: 189 Supplier: 89536
Opt Part #: 21 Supplier: 89536
Opt Part #: 27 Supplier: 89536
Opt Part #: 77 SERIES III Supplier: 89536
Opt Part #: 87 Supplier: 89536
Opt Part #: FLUKE 27 Supplier: 89536
Opt Part #: MODEL 27 Supplier: 89536
D. Location Zones
Zone Area
116 Nose Landing Gear Wheel Well - Right
E. Access Panels
Number Name/Location
114AR External Power Receptacle Door
F. Procedure
SUBTASK 24-41-11-860-008
(1) Do this task: Remove Electrical Power, TASK 24-22-00-860-812.
SUBTASK 24-41-11-010-010
(2) Open this access panel if it is closed:
Number Name/Location
114AR External Power Receptacle Door
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
24-41-11
Page 619
D633A101-ILF Jun 15/2019
ECCN 9E991 BOEING PROPRIETARY - Copyright © Unpublished Work - See title page for details
EFFECTIVITY
ILF ALL