DUAL BATTERY REMOTE CONTROL CIRCUIT BREAKER (RCCB) - ADJUSTMENT/TEST
1. General
A. This procedure contains scheduled maintenance task data.
B. This procedure has this task:
(1) The Operational Test of the Dual Battery RCCB
TASK 24-31-41-710-801
2. Operational Test for the Dual Battery RCCB
(Figure 501)
NOTE: This procedure is a scheduled maintenance task.
A. References
Reference Title
24-22-00-860-813 Supply External Power (P/B 201)
24-22-00-860-814 Remove External Power (P/B 201)
B. Location Zones
Zone Area
117 Electrical and Electronics Compartment - Left
121 Forward Cargo Compartment - Left
122 Forward Cargo Compartment - Right
211 Flight Compartment - Left
212 Flight Compartment - Right
C. Access Panels
Number Name/Location
117A Electronic Equipment Access Door
D. Prepare for Test
SUBTASK 24-31-41-860-005
(1) Do this task: Supply External Power, TASK 24-22-00-860-813.
SUBTASK 24-31-41-860-006
(2) Set the STANDBY POWER switch on the P5-5 panel to the OFF position.
SUBTASK 24-31-41-860-007
(3) Set the BAT switch on the P5-13 panel to the OFF position.
SUBTASK 24-31-41-010-002
(4) Open this access panel:
Number Name/Location
117A Electronic Equipment Access Door
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
24-31-41
Page 501
D633A101-ILF Jun 15/2019
ECCN 9E991 BOEING PROPRIETARY - Copyright © Unpublished Work - See title page for details
EFFECTIVITY
ILF 101, 151, 156-199, 301, 304, 308, 310, 314, 315, 317-319, 323, 331-399, 401,
402, 405, 406, 409, 410, 412, 416, 424, 425, 427-429, 451, 452, 491-504, 507-510,
512-516, 518-520, 523-528, 530-533, 535-537, 541, 542, 552-557, 559-561, 563,
564, 567-569, 571-577, 581, 583, 585, 589, 590, 597-599, 601-603, 606, 607,
610-615, 620, 625-627, 671, 672, 691-699, 703, 803-813, 821, 822, 831, 832,
835-838, 841, 842, 851, 852, 857, 858, 947, 948, 968-973, 980-999