EasyManua.ls Logo

Boeing 737-600 - Subtask 53-12-11-620-001; Subtask 53-12-11-210-002; Subtask 53-12-11-210-003; Subtask 53-12-11-420-001

Boeing 737-600
2300 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SUBTASK 53-12-11-620-001
CAUTION
APPLY PRESSURE WITH YOUR HAND TO INSTALL THE PANEL. DO NOT
DAMAGE OR PRELOAD THE PANEL DURING THE INSTALLATION. REMOVE
ALL THE UNWANTED SEALANT FROM THE INNER AND THE OUTER AREA
OF THE PANEL. USE THE MINIMUM SEALANT TO PREVENT A PANEL OUT
OF THE FAIR CONDITION.
(5) Apply the sealant, A00247 to the inner faces of the panel mating surfaces immediately before
the panel installation.
NOTE: You can apply the sealant as a continuous or broken seal (Ref 51-31-00/201).
SUBTASK 53-12-11-210-002
(6) Examine the attachment clips for damage.
SUBTASK 53-12-11-210-003
(7) Examine the door for free motion at the hinge line.
SUBTASK 53-12-11-420-001
CAUTION
USE THE RECOMMENDED RIVETS TO GET THE CORRECT FUNCTION OF
THE BLOWOUT PANEL.
(8) If the panel has opened due to excess pressure, then re-install the panel to the "T" structure
with two rivets.
SUBTASK 53-12-11-420-002
(9) If the panel has been open for inspection, then attach the panel assembly to airplane with 4
screws.
END OF TASK
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
53-12-11
Page 402
D633A101-ILF Oct 15/2017
ECCN 9E991 BOEING PROPRIETARY - Copyright © Unpublished Work - See title page for details
EFFECTIVITY
ILF ALL

Table of Contents