SUBTASK 47-32-01-030-001
(3) Disconnect the electrical connector [7].
SUBTASK 47-32-01-030-002
(4) Disconnect the bonding jumper [12].
SUBTASK 47-32-01-020-001
(5) Do these steps to disconnect the NGS shutoff valve [1] from the bleed air inlet duct [2].
(a) Disconnect the coupling [4].
1) Keep the coupling [4] for the installation.
SUBTASK 47-32-01-020-002
(6) Do these steps to disconnect the NGS shutoff valve [1] from the ozone converter [6]:
(a) Hold the NGS shutoff valve [1] in its position.
(b) Disconnect the coupling [5].
1) Keep the coupling [5] for the installation.
(c) Remove the NGS shutoff valve [1].
(d) Keep the seal [3].
SUBTASK 47-32-01-490-001
(7) Install protective covers on the open bleed air inlet duct [2] and ozone converter [6].
END OF TASK
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
47-32-01
Page 403
D633A101-ILF Oct 15/2019