(f) Make sure the DC meter on the P5-13 panel shows this value:
1) DC VOLTS = 22-30
(g) Set the DC Meter Selector Switch on the P5-13 panel to the TR 3 position.
(h) Make sure the DC meter on the P5-13 panel shows this value:
1) DC VOLTS = Less than 10
(i) Remove the safety tags and close these circuit breakers:
Power Distribution Panel Number 1, P91
Row Col Number Name
A 4 C00941 TRU 3 ALTN
Power Distribution Panel Number 2, P92
Row Col Number Name
A 6 C00808 TRU 3
E. Put the airplane in its usual condition.
SUBTASK 24-31-00-860-003
(1) Do this task: Remove Electrical Power, TASK 24-22-00-860-812.
END OF TASK
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
24-31-00
Page 504
D633A101-ILF Jun 15/2015