SUBTASK 53-05-02-410-115
(3) Close this access panel:
Number Name/Location
822 Aft Cargo Door
END OF TASK
TASK 53-05-02-250-950
196. INTERNAL - SPECIAL DETAILED: AFT CARGO DOOR SURROUND STRUCTURE
NOTE: This procedure is a scheduled maintenance task.
A. Location Zones
Zone Area
142 Aft Cargo Compartment - Right
144 Area Below Aft Cargo Compartment - Right
B. Access Panels
Number Name/Location
822 Aft Cargo Door
C. Inspection
SUBTASK 53-05-02-010-114
(1) Open this access panel:
Number Name/Location
822 Aft Cargo Door
SUBTASK 53-05-02-250-150
(2) Do a High Frequency Eddy Current inspection of the bearstrap for two inches on each side of
stringer S-24R at STA 794.4 and STA 847. (PSE 53-60-08-6)
See Doc D626A001-DTR, DTR check form 53-30-08-6 for alternative inspections.
SUBTASK 53-05-02-410-112
(3) Close this access panel:
Number Name/Location
822 Aft Cargo Door
END OF TASK
TASK 53-05-02-130-809
197. INTERNAL - SPECIAL DETAILED: AFT CARGO DOOR SURROUND STRUCTURE
NOTE: This procedure is a scheduled maintenance task.
A. Location Zones
Zone Area
142 Aft Cargo Compartment - Right
144 Area Below Aft Cargo Compartment - Right
B. Access Panels
Number Name/Location
822 Aft Cargo Door
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
53-05-02
Page 298.22
D633A101-ILF Oct 15/2019
ECCN 9E991 BOEING PROPRIETARY - Copyright © Unpublished Work - See title page for details
EFFECTIVITY
ILF ALL