The NDI method(s) necessary to accomplish the intent of this inspection is contained in the
737 Nondestructive Test Manual (D6-37239). The inspection procedures are contained in Part
6, Subject 53-10-83.
SUBTASK 53-05-02-410-100
(3) Close this access panel:
Number Name/Location
844 Aft Galley Service Door
END OF TASK
TASK 53-05-02-250-900
145. INTERNAL - SPECIAL DETAILED: AFT GALLEY DOOR FORWARD EDGE FRAME DOOR STOP
BACKUP STRUCTURE
NOTE: This procedure is a scheduled maintenance task.
A. Location Zones
Zone Area
242 Aft Passenger Compartment - Station 663.75 to Aft Pressure Bulkhead - Right
B. Access Panels
Number Name/Location
844 Aft Galley Service Door
C. Inspection
SUBTASK 53-05-02-010-104
(1) Open this access panel:
Number Name/Location
844 Aft Galley Service Door
NOTE: Remove or displace passenger cabin sidewall and ceiling lining as required to perform
the inspection.
SUBTASK 53-05-02-250-100
(2) Do a High Frequency Eddy Current inspection on the four fastener locations at the #1, #2, #5
and #6 stop locations. For door stop #5, there are two locations in the strap hidden by the
bracket.
See Doc D626A001-DTR, DTR check form 53-70-08-3 for alternative inspections.
The NDI method(s) necessary to accomplish the intent of this inspection is contained in the
737 Nondestructive Test Manual (D6-37239). The inspection procedures are contained in Part
6, Subject 53-10-83.
SUBTASK 53-05-02-410-102
(3) Close this access panel:
Number Name/Location
844 Aft Galley Service Door
END OF TASK
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
53-05-02
Page 292
D633A101-ILF Oct 15/2019
ECCN 9E991 BOEING PROPRIETARY - Copyright © Unpublished Work - See title page for details
EFFECTIVITY
ILF ALL