SUBTASK 24-11-00-700-003
NOTE: Engines should not be operating during the tryout procedure.
(2) Make sure the engines are not operating, if the engines are operating, then do this task: Stop
the Engine Procedure (Usual Engine Stop), TASK 71-00-00-700-819-F00.
SUBTASK 24-11-00-700-004
(3) Open this access panel:
Number Name/Location
117A Electronic Equipment Access Door
(a) Make sure the LED lights on the front panel of the Generator Control Unit are not
illuminated.
END OF TASK