EasyManua.ls Logo

Boeing 737-600 - Subtask 30-11-41-860-013; Subtask 30-11-41-860-014; Subtask 30-11-41-710-001; Subtask 30-11-41-710-002

Boeing 737-600
2300 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SUBTASK 30-11-41-860-013
(5) Make sure that these circuit breakers are closed:
CAPT Electrical System Panel, P18-3
Row Col Number Name
A 1 C00146 ANTI-ICE & RAIN WING ANTI-ICE VALVE
A 6 C00148 ANTI-ICE & RAIN ENG 1 & WING CONT
A 7 C01001 ANTI-ICE & RAIN ENG 1 COWL AI VALVE
B 6 C00149 ANTI-ICE & RAIN ENGINE 2 CONTROL
B 7 C01002 ANTI-ICE & RAIN ENG 2 COWL AI VALVE
F. Engine and Wing Anti-Ice Panel Installation Test
SUBTASK 30-11-41-860-014
(1) Do this task: Supply External Power, TASK 24-22-00-860-813.
SUBTASK 30-11-41-710-001
(2) Put the MASTER DIM AND TEST switch, S3, on the P1-3 main captain panel to the TEST
position.
(a) Make sure the COWL VALVE OPEN indicators on the anti-ice panel turn blue.
SUBTASK 30-11-41-710-002
(3) Put the MASTER DIM and TEST switch to the BRT position.
END OF TASK
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
30-11-41
Page 406
D633A101-ILF Oct 15/2018
ECCN 9E991 BOEING PROPRIETARY - Copyright © Unpublished Work - See title page for details