EasyManua.ls Logo

Boeing 737-600 - Subtask 30-42-31-700-002; Subtask 30-42-31-860-008; Subtask 30-42-31-860-009

Boeing 737-600
2300 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SUBTASK 30-42-31-700-002
(6) Measure the force of the wiper arm again.
SUBTASK 30-42-31-860-008
(7) Put the windshield wiper back to its usual position:
(a) Turn the applicable wiper switch to PARK.
CAUTION
DO NOT OPERATE THE WINDSHIELD WIPER ON DRY GLASS. THE
WIPER WILL CAUSE DAMAGE TO THE WINDSHIELD. ALWAYS SUPPLY
WATER TO THE WINDSHIELDS BEFORE YOU OPERATE THE WIPER.
(b) Supply a continuous spray of clean water to the windshield.
NOTE: For windshields with a hydrophobic coating, deionized or distilled water is
recommended during the wiper test. Water with a high mineral content can cause
marks on the coated glass surface that are difficult to remove. If water with a high
mineral content is used on a windshield with a hydrophobic coating, flush the
windshield surface after the wiper test with deionized or distilled water, or remove
the remaining water on the windshield with a cotton cloth.
(c) Remove the safety tags and close these circuit breakers:
CAPT Electrical System Panel, P18-3
Row Col Number Name
B 1 C00055 ANTI-ICE & RAIN WSHLD WIPER RIGHT
B 3 C00054 ANTI-ICE & RAIN WSHLD WIPER LEFT
(d) Make sure the wiper blade stops in the parked position.
(e) Stop the water spray.
F. Put the Airplane Back to Its Usual Condition
SUBTASK 30-42-31-860-009
(1) Remove the safety tags and close these circuit breakers:
CAPT Electrical System Panel, P18-3
Row Col Number Name
C 1 C00523 HEATERS CAPT PITOT
D 1 C00226 WINDOW HEAT CONTROL RIGHT FRONT AC
D 2 C00225 WINDOW HEAT CONTROL LEFT SIDE AC
D 5 C00525 HEATERS F/O PITOT
D 6 C00524 HEATERS AUX PITOT
E 1 C00224 WINDOW HEAT CONTROL LEFT FRONT AC
E 2 C00227 WINDOW HEAT CONTROL RIGHT SIDE AC
F/O Electrical System Panel, P6-11
Row Col Number Name
ILF 568, 583, 588, 592-596, 671, 672, 832, 836, 837, 841, 842, 968-970, 972, 973, 980-999
B 7 C01650 WINDOW HEAT POWER L3
ILF 301, 304, 308, 310, 314, 315, 317-319, 323, 331-399, 401, 424, 425, 427-429, 507, 533, 535, 537,
556, 557
B 7 C00229 WINDOW HEAT POWER L3, L4 & L5
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
30-42-31
Page 215
D633A101-ILF Feb 15/2019
ECCN 9E991 BOEING PROPRIETARY - Copyright © Unpublished Work - See title page for details