(a) If the particles are found, carefully remove and keep the particles with a cotton wiper,
G00034 or thin sheet of paper.
(b) Send the particles to the laboratory for analysis.
SUBTASK 80-11-02-110-001-F00
WARNING
DO NOT GET SOLVENT IN YOUR MOUTH OR EYES, OR ON YOUR SKIN. DO
NOT BREATHE THE FUMES FROM THE SOLVENT. PUT ON A PROTECTIVE
SPLASH GOGGLE AND GLOVES WHEN YOU USE THE SOLVENT. KEEP THE
SOLVENT AWAY FROM SPARKS, FLAME AND HEAT. SOLVENT IS
POISONOUS AND FLAMMABLE WHICH CAN CAUSE INJURIES TO
PERSONS OR DAMAGE TO EQUIPMENT.
(3) After you remove all of the particles, clean the QAD adapter [1] with the solvent, B00682
[CP2011].
(a) Dry the QAD adapter [1] with an 0-30 psig dry filtered regulated air source, STD-1280.
(b) Make sure that the QAD adapter [1] is free of all particles.
END OF TASK
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
CFM56 ENGINES (CFM56-7)
80-11-02
Page 402
D633A101-ILF Oct 15/2018
ECCN 9E991 BOEING PROPRIETARY - Copyright © Unpublished Work - See title page for details
EFFECTIVITY
ILF ALL