(c) Stop the number 1 engine. To stop the number 1 engine, do this task: Stop the Engine
Procedure (Usual Engine Stop), TASK 71-00-00-700-819-F00.
SUBTASK 24-22-00-860-018
(2) Do these steps to remove IDG 2 power from the 115V AC transfer buses:
(a) Set the GEN 2 control switch on the P5-4 panel to the OFF position.
NOTE: It is sufficient to shut down the engine without setting the GEN 2 switch to OFF.
(b) Make sure the 2 GEN OFF BUS light on the P5-4 panel comes on.
(c) Stop the number 2 engine. To stop the number 2 engine, do this task: Stop the Engine
Procedure (Usual Engine Stop), TASK 71-00-00-700-819-F00.
E. Put the Airplane into its Usual Condition
SUBTASK 24-22-00-860-022
(1) Set the BAT switch on the P5-13 panel to the OFF position.
END OF TASK