DGS-3610 Series Configuration Guide Chapter 26 Configuration of RMON
26-3
Caution
The current version of our product supports only the records of Ethernet.
The index value should be within 1-65535. At most 10 control entry can be
configured.
Bucket-number: the control entry specifies the used data source and time interval. Each
sampling interval should be sampled once. The sampling results are saved. The
Bucket-number specifies the maximum number of sampling. When the maximum is reached
for the sampling records, the new one will overwrite the earliest one. The value range of
Bucket-number is 1-65535. Its default value is 10.
Interval: the time interval of sampling. Its default value is 1800 seconds, and its value range
is 1-3600.
26.2.3 Configuring Alarm and Event
One of these command can be used to configure the alarm form:
Command
Function
DGS-3610(config)# rmon alarm number
variable interval {absolute | delta}
rising-threshold value [event-number]
falling-threshold value [event-number] [owner
ownername]
Add an entry of history control.
DGS-3610(config)# rmon event number [log]
[trap community] [description
description-string]
Add an entry of Event.
DGS-3610(config)# no rmon alarm number
Remove an alarm.
DGS-3610(config)# no rmon event number
Remove an event.
Number: the index of alarm form (event form) with the range of 1-65535.
Variable: the variable monitored by the alarm form. The variable must be an integer.
Interval: the time interval of sampling. Its range is 1-4294967295.
The keyword Absolute indicates each sampling value compared with the high and low limits.
The keyword Delta indicates the difference with previous sampling value compared with the
high and low limits.
Value defines the values of high limit and low limit.
Event-number: when the value exceeds the high or low limit, the event with the index of
Event-number will be triggered.
The keyword Log indicates the action triggered by the event is to record the event.

Table of Contents

Other manuals for D-Link xStack DGS-3610 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link xStack DGS-3610 Series and is the answer not in the manual?

D-Link xStack DGS-3610 Series Specifications

General IconGeneral
BrandD-Link
ModelxStack DGS-3610 Series
CategorySwitch
LanguageEnglish

Related product manuals