EasyManuals Logo

Enterasys SecureStack C2 User Manual

Enterasys SecureStack C2
607 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #116 background imageLoading...
Page #116 background image
set ciscodp holdtime
4-10 Discovery Protocol Configuration
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosettheCiscoDPtimerto120seconds.
C2(su)->set ciscodp timer 120
set ciscodp holdtime
Usethiscommandtosetthetimetolive(TTL)forCiscodiscoveryprotocolPDUs.Thisisthe
amountoftime,insecond s,neighboringdeviceswillholdPDUtransmissionsfromthesending
device.
Syntax
set ciscodp holdtime hold-time
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetCiscoDPholdtimeto180seconds:
C2(su)->set ciscodp hold-time 180
set ciscodp port
Usethiscommandtosetthestatus,voiceVLAN,extendedtrustmode,andCoSpriorityfor
untrustedtrafficfortheCiscoDiscoveryProtocolononeormoreports.
Syntax
set ciscodp port {[status {disable | enable}] [vvid {vlan-id | none | dot1p |
untagged}] [trusted {yes | no}] [cos value]} port-string
holdtime SpecifiesthetimetoliveforCiscoDPPDUs.Validvaluesarefrom10to255
seconds.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals