set port trap
5-20 Port Configuration
Parameters
Defaults
Ifportstringisnotspecified,thetrapstatusforallportswillbedisplayed.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtodisplaylinktrapstatusforge.3.1through4:
C2(su)->show port trap ge.3.1-4
Link traps enabled on port ge.3.1.
Link traps enabled on port ge.3.2.
Link traps enabled on port ge.3.3.
Link traps enabled on port ge.3.4.
set port trap
UsethiscommandtoenableofdisableportsforsendingSNMPtrapmessageswhentheirlink
statuschanges.
Syntax
set port trap port-string {enable | disable}
Parameters
Defaults
Sendingtrapswhenlinkstatuschangesisenabledbydefault.
Mode
Switchcommand,readwrite.
Example
Thefollowingexampledisablessendingtraponge.3.1.
C2(su)->set port trap ge.3.1 disable
portstring (Optional)Displayslinktrapstatusforspecificport(s).Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLIonpage52.
portstring Specifiestheport(s)forwhichtoenableordisableporttraps.For a
detaileddescriptionofpossibleportstringvalues,refertoPortString
SyntaxUsedintheCLIonpage52.
enable|disable Enablesordisablessendingtrapmessageswhenlinkstatuschanges.