17-24 IPv4 Routing Protocol Configuration
Parameters
Defaults
None.
Mode
Routerconfiguration:C2(su)>router(Configrouter)#
Example
Thisexampleshowshowtoconfigureavirtuallinkovertransitionarea0.0.0.2torouterID
192.168.7.2:
C2(su)->router(Config)#router ospf 1
C2(su)->router(Config-router)#area 0.0.0.2 virtual-link 192.168.7.2
redistribute
UsethiscommandtoallowroutinginformationdiscoveredthroughnonOSPFprotocolstobe
distributedinOSPFupdatemessages.Thenoformofthiscommandclearsredistribution
parameters.
Syntax
redistribute {connected | rip | static} [metric metric value] [metric-type type-
value] [subnets]
no redistribute {connected | rip | static}
areaid Specifiesthetransitareaforthevirtuallink.Validvaluesaredecimalvalues
orIPaddresses.Atransitareaisanareathroughwhichavirtuallinkis
established.
routerid SpecifiestherouterIDofthevirtuallinkneighbor.
authentication‐
keykey
Specifiesapasswordtobeusedbythe
virtuallink.Validvaluesare
alphanumericstringsofupto8characters.Neighborvirtuallinkrouterson
anetworkmusthavethesamepassword.
deadinterval
seconds
Specifiesthenumberofsecondsthataroutermustwaittoreceiveahello
packetbeforedeclaringtheneighboras“dead”andremovingit
fromthe
OSPFneighborlist.Thisvaluemustbethesameforallvirtuallinksattached
toacertainsubnet,anditisavaluerangingfrom1to8192.
hellointerval
seconds
Specifiesthenumberofsecondsbetweenhellopacketsonthevirtuallink.
Thisvaluemustbethesame
forallvirtuallinksattachedtoanetworkandit
isavaluerangingfrom1to8192.
retransmit
intervalseconds
Specifiesthenumberofsecondsbetweensuccessiveretransmissionsofthe
sameLSAs.Validvaluesaregreaterthanthe expectedamountoftime
requiredfortheupdatepackettoreachand
returnfromtheinterface,and
rangefrom1to8192.Defaultis5seconds.
transmitdelay
seconds
Specifiestheestimatednumberofsecondsbeforealinkstateupdatepacket
ontheinterfacetobetransmitted.Validvaluesrangefrom1to8192.Default
is1second.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals