clear port priority
SecureStack C2 Configuration Guide 10-3
5,theframesreceivedthroughthatportwithoutapriorityindicatedintheirtagheaderare
classifiedasapriority5.
Aframewithpriorityinformationinitstagheaderistransmittedaccordingtothatpriority.
Syntax
set port priority port-string priority
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtosetadefaultpriorityof6onge.1.3.Framesreceivedbythisport
withoutpriorityinformationintheirframeheaderaresettothedefaultsettingof6:
C2(su)->set port priority ge.1.3 6
clear port priority
UsethiscommandtoresetthecurrentCoSportprioritysettingto0.Thiswillcauseallframes
receivedwithoutapriorityvalueinitsheadertobesettopriority0.
Syntax
clear port priority port-string
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoresetge.1.11tothedefaultpriority:
portstring Specifiestheportforwhichtosetpriority.Foradetaileddescriptionof
possibleportstringvalues,refertoPortStringSyntaxUsedintheCLIon
page 52.
priority Specifiesavalueof0to7tosettheCoSpriorityfortheport
enteredinthe
portstring.Priorityvalueof 0isthelowestpriority.
portstring Specifiestheportforwhichtoclearpriority.Foradetaileddescriptionof
possibleportstringvalues,refertoPortStringSyntaxUsedintheCLIon
page 52.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals