EasyManua.ls Logo

Enterasys SecureStack C2

Enterasys SecureStack C2
607 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
show rmon channel
SecureStack C2 Configuration Guide 13-15
Onechannelatatimecanbesupported,withuptothreefilters.Configuredchannel,filter,and
buffercontrolinformationwillbesavedacrossresets,butcapturedframeswithinthebufferwill
notbesaved.
Thisfunctioncannotbeusedconcurrentlywithportmirroring.Thesystemwillchecktoprevent
concurrently
enablingbothfunctions,andawarningwillbegeneratedintheCLIifattempted.
Commands
show rmon channel
UsethiscommandtodisplayRMONchannelentriesforoneormoreports.
Syntax
show rmon channel [port-string]
Parameters
Defaults
Ifportstringisnotspecified,informationaboutallchannelswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplayRMONchannelinformationforge.2.12:
C2(rw)->show rmon channel ge.2.12
Port ge.2.12 Channel index= 628 EntryStatus= valid
----------------------------------------------------------
Control off AcceptType matched
OnEventIndex 0 OffEventIndex 0
EventIndex 0 Status ready
Matches 4498
Description Thu Dec 16 12:57:32 EST 2004
Owner NetSight smith
For information about... Refer to page...
show rmon channel 13-15
set rmon channel 13-16
clear rmon channel 13-16
show rmon filter 13-17
set rmon filter 13-18
clear rmon filter 13-18
portstring (Optional)DisplaysRMONchannelentriesforaspecificport(s).

Table of Contents