show rmon channel
SecureStack C2 Configuration Guide 13-15
Onechannelatatimecanbesupported,withuptothreefilters.Configuredchannel,filter,and
buffercontrolinformationwillbesavedacrossresets,butcapturedframeswithinthebufferwill
notbesaved.
Thisfunctioncannotbeusedconcurrentlywithportmirroring.Thesystemwillchecktoprevent
concurrently
enablingbothfunctions,andawarningwillbegeneratedintheCLIifattempted.
Commands
show rmon channel
UsethiscommandtodisplayRMONchannelentriesforoneormoreports.
Syntax
show rmon channel [port-string]
Parameters
Defaults
Ifportstringisnotspecified,informationaboutallchannelswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplayRMONchannelinformationforge.2.12:
C2(rw)->show rmon channel ge.2.12
Port ge.2.12 Channel index= 628 EntryStatus= valid
----------------------------------------------------------
Control off AcceptType matched
OnEventIndex 0 OffEventIndex 0
EventIndex 0 Status ready
Matches 4498
Description Thu Dec 16 12:57:32 EST 2004
Owner NetSight smith
For information about... Refer to page...
show rmon channel 13-15
set rmon channel 13-16
clear rmon channel 13-16
show rmon filter 13-17
set rmon filter 13-18
clear rmon filter 13-18
portstring (Optional)DisplaysRMONchannelentriesforaspecificport(s).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals