EasyManuals Logo
Home>Enterasys>Switch>SecureStack C2

Enterasys SecureStack C2 User Manual

Enterasys SecureStack C2
607 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #485 background imageLoading...
Page #485 background image
timers spf
SecureStack C2 Configuration Guide 17-15
Parameters
Defaults
None.
Mode
Interfaceconfiguration:C2(su)>router(Configif(Vlan1))#
Usage
Thepriorityvalueiscommunicatedbetweenroutersbymeansofhellomessagesandinfluences
theelectionofadesignatedrouter.
Example
ThisexampleshowshowtosettheOSPFpriorityto20fortheVLAN1interface:
C2(su)->router(Config)#interface vlan 1
C2(su)->router(Config-if(Vlan 1))#ip ospf priority 20
timers spf
UsethiscommandtochangeOSPFtimervaluestofinetunetheOSPFnetwork.Thenoformof
thiscommandrestoresthedefaulttimervalues(5secondsfordelayand10secondsforholdtime).
Syntax
timers spf spf-delay spf-hold
no timers spf
Parameters
Defaults
None.
Mode
Routerconfiguration:C2(su)>router(Configrouter)#
Example
ThisexampleshowshowtosetSPFdelaytimeto7secondsandholdtimeto3:
C2(su)->router(Config)#router ospf 1
C2(su)->router(Config-router)#timers spf 7 3
number SpecifiestheroutersOSPFpriorityinarangefrom0to255.Defaultvalueis
1.
spfdelay Specifiesthedelay,inseconds,betweenthereceiptofanupdateandtheSPF
execution.Validvaluesare 0 to4294967295.
spfhold Specifiestheminimumamountoftime,inseconds,betweentwo
consecutiveOSPFcalculations.Validvaluesare0to4294967295.Avalueof
0meansthattwo
consecutiveOSPFcalculationsareperformedone
immediatelyaftertheother.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals