show vlanauthorization
SecureStack C2 Configuration Guide 18-45
Defaults
Ifnoportstringisentered,allportsawillberesettodefaultconfigurationwithVLAN
authorizationdisabledandegressframesuntagged.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowhowtoclearVLANauthorizationforallportsonslots3,4,and5:
C2(rw)->clear vlanauthorization ge.3-5.*
show vlanauthorization
DisplaystheVLANauthenticationstatusandconfigurationinformationforthespecifiedports.
Syntax
show vlanauthorization [port-string]
Parameters
Defaults
Ifnoportstringisentered,thestatusforallportswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThiscommandshowshowtodisplayVLANauthorizationstatusforge.1.1:
C2(rw)-> show vlanauthorization ge.1.1
port status administrative egress operational egress vlan id
----- ------- ------------------------- --------------------- --------
ge.1.1 enabled untagged none 0
Table 185providesanexplanationofcommandoutput.Fordetailsonenablingandassigning
protocolandegressattributes,refertosetvlanauthorizationonpage 1843andset
vlanauthorizationegressonpage 1844.
portstring (Optional)DisplaysVLANauthenticationstatusforthespecifiedports.If
noportstringisentered,thentheglobalstatusofthesettingisdisplayed.
Foradetaileddescriptionofpossibleportstringvalues,refertoPort
StringSyntaxUsedintheCLIonpage 52.
Table 18-5 show vlanauthorization Output Details
Output What It Displays...
port Port identification
status Port status as assigned by set vlanauthorization command