EasyManua.ls Logo

Enterasys SecureStack C2

Enterasys SecureStack C2
607 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
set vlanauthorization egress
18-44 Security Configuration
C2(rw)-> set vlanauthorization disable ge.3.*
set vlanauthorization egress
ControlsthemodificationofthecurrentVLANegresslistof802.1xauthenticatedportsforthe
VLANsreturnedintheRADIUSauthorizationfilteridstring.
Syntax
set vlanauthorization egress {none | tagged | untagged} port-string
Parameters
Defaults
Bydefault,administrativeegressissettountagged.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoenabletheinsertionoftheRADIUSassignedVLANtoan802.1qtag
foralloutboundframesforports10through15onunit/modulenumber3.
C2(rw)->set vlanauthorization egress tagged ge.3.10-15
clear vlanauthorization
Usethiscommandtoreturnport(s)tothedefaultconfigurationofVLANauthorizationdisabled,
egressuntagged.
Syntax
clear vlanauthorization [port-string]
Parameters
none Specifiesthatnoegressmanipulationwillbemade.
tagged Specifiesthattheauthenticatingportwillbeaddedtothecurrenttagged
egressfortheVLANIDreturned.
untagged Specifiesthattheauthenticatingportwillbeaddedtothecurrent
untaggedegressfortheVLANIDreturned(default).
portstring Specifiesthattheport
orlistofports.towhichthiscommandwillapply.
Foradetaileddescriptionofpossibleportstringvalues,refertoPort
StringSyntaxUsedintheCLIonpage 52.
portstring (Optional)Specifieswhichportsaretoberestoredtodefault
configuration.Ifnoportstringisentered,theactionwillbeaglobal
setting.Foradetaileddescriptionofpossibleportstringvalues,referto
PortStringSyntaxUsedintheCLIonpage 52.