show ip pimsm rphash
SecureStack C2 Configuration Guide 17-53
show ip pimsm rphash
DisplaystheRendezvousPointrouterthatwillbeselectedfromthesetofactiveRProuters.The
RProuter,forthegroup,isselectedbyusingthehashalgorithmdefinedinRFC2362.
Syntax
show ip pimsm rphash group-address
Parameters
Defaults
None.
Mode
Anyroutermode.
Example
ThisexampleshowshowtodisplayRPthatwillbeselectedforgroupaddress224.0.0.0:
C2(su)->router> show ip pimsm rphash 224.0.0.0
192.168.129.223
show ip pimsm staticrp
DisplaythePIMSMstaticRendezvousPointinformation.
Syntax
show ip pimsm staticrp
Parameters
None.
Mode
Anyroutermode.
Defaults
None.
Example
ThisexampleshowshowtodisplayPIMinformation.
C2(su)->router# show ip pimsm staticrp
STATIC RP TABLE
Address Group Address Group Mask
--------------- --------------- ---------------
123.231.111.121 234.0.0.0 255.0.0.0
192.168.129.223 224.0.0.0 240.0.0.0
groupaddress TheGroupAddressfortheRP.