show spantree backuproot
SecureStack C2 Configuration Guide 7-21
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtogloballyresetthebridgeforwarddelay:
C2(su)->clear spantree fwddelay
show spantree backuproot
UsethiscommandtodisplaythebackuprootstatusforanMSTinstance.
Syntax
show spantree backuproot [sid]
Parameters
Defaults
IfaSIDisnotspecified,thenstatuswillbeshownforSpanningTreeinstance0.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaythestatusofthebackuprootfunctiononSID0:
C2(rw)->show spantree backuproot
Backup root is set to disable on sid 0
set spantree backuproot
UsethiscommandtoenableordisabletheSpanningTreebackuprootfunctionontheswitch.
Syntax
set spantree backuproot sid {disable | enable}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
sid (Optional)DisplaybackuprootstatusforaspecificSpanningTree
identifier.Validvaluesare0‐4094.Ifnotspecified,SID0isassumed.
sid SpecifiestheSpanningTreeinstanceonwhichtoenableordisablethe
backuprootfunction.Validvaluesare0‐4094.
disable|enable Enablesordisablesthebackuprootfunction.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals