Page #394 background image
Configuring Node Aliases
12-32 Logging and Network Management
Configuring Node Aliases
Purpose
Toreview,disable,andreenablenode(port)aliasfunctionality,which determineswhatnetwork
protocolsarerunningononeormoreports.
Commands
show nodealias config
Usethiscommandtodisplaynodealiasconfigurationsettingsononeormoreports.
Syntax
show nodealias config [port-string]
Parameters
Defaults
Ifportstringisnotspecified,nodealiasconfigurationswillbedisplayedforallports.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaynodealiasconfigurationsettingsforportsge.2.1through9:
C2(rw)->show nodealias config ge.2.1-9
Port Number Max Entries Used Entries Status
----------- ----------- ------------ ------
ge.2.1 16 0 Enable
ge.2.2 47 0 Enable
ge.2.3 47 2 Enable
ge.2.4 47 0 Enable
ge.2.5 47 0 Enable
ge.2.6 47 2 Enable
ge.2.7 47 0 Enable
ge.2.8 47 0 Enable
ge.2.9 4000 1 Enable
Table 127providesanexplanationofthecommandoutput.
For information about... Refer to page...
show nodealias config 12-32
set nodealias 12-33
clear nodealias config 12-34
portstring (Optional)Displaysnodealias conf igurationsettingsforspecificport(s).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals