18-60 Security Configuration
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoenableportwebauthentication:
C2(su)->set pwa enable
show pwa banner
Usethiscommandtodisplaytheportwebauthenticationloginbannerstring.
Syntax
show pwa banner
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaythePWAloginbanner:
C2(su)->show pwa banner
Welcome to Enterasys Networks
set pwa banner
UsethiscommandtoconfigureastringtobedisplayedasthePWAloginbanner.
Syntax
set pwa banner string
Parameters
Defaults
None.
string SpecifiesthePWAloginbanner.