Page #263 background image
show spantree adminedge
SecureStack C2 Configuration Guide 7-37
Parameters
Defaults
Ifsidisnotspecified,adminpathcostwillberesetforSpanningTree0.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoresettheadminpathcostto0forge.3.2onSID1:
C2(su)->clear spantree adminpathcost ge.3.2 sid 1
show spantree adminedge
Usethiscommandtodisplaytheedgeportadministrativestatusforaport.
Syntax
show spantree adminedge [port port-string]
Parameters
Defaults
IfportstringisnotspecifiededgeportadministrativestatuswillbedisplayedforallSpanning
Treeports.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaytheedgeportstatusforge.3.2:
C2(su)->show spantree adminedge port ge.3.2
Port ge.3.2 has a Port Admin Edge of Edge-Port
set spantree adminedge
UsethiscommandtosettheedgeportadministrativestatusonaSpanningTreeport.
portstring Specifiestheport(s)forwhichtoresetadminpathcost.Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntax
UsedintheCLIonpage 52.
sidsid (Optional)Resets
theadminpathcostforspecificSpanningTree(s).
Validvaluesare0‐4094.If notsp ecified,SID0isassumed.
portstring (Optional)Displaysedgeportadministrativestatusforspecific
port(s).Foradetaileddescriptionofpossibleportstringvalues,
refertoPortStringSyntaxUsedintheCLIonpage 52.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals